Suction power will not decrease during extended use or suction of highly viscous fumes caused by laser marking, which typically cause filter clogging.
*Compared with our existing products
Model | Primary filter | Secondary filter | Exhaust filter | Activated carbon filter
(Activated carbon amount approx. 3kg) |
---|---|---|---|---|
CBA-1000AT3-HC-DSA-V1 | HDF-3535-120-ZEO | CHF-2030-50 | HEP-3220-69 | ACC-3220-100 |
Size | Type |
---|---|
φ38 | FRJ-D-38-35-108 |
φ50 | FRJ-D-50-35-108 |
φ65 | FRJ-D-65-35-108 |
Model | Output | Voltage | Frequency | Rated current |
---|---|---|---|---|
CBA-1000AT3-HC-DSA-V1 | 500W | 100V (single phase) | 50/60 | 7.8A |
Maximum air flow *1*2
|
Maximum static pressure |
Noise level
*3
|
Suction port (hose) size |
Suction port sold separately (size can be changed) |
---|---|---|---|---|
3.2㎥/min | 9.3-9.5kPa | 54-59dB | φ75 | φ65 ・φ50 ・φ38 |
To be used with 200-240V |
CE compliant | Panel | Power cable | Filter cleaning function |
---|---|---|---|---|
AT3 | 3m | Vibration type |
Remote control feature |
Suitable for use in clean rooms |
Primary filter capacity *4
|
Mass | Main body dimensions (D×W×H) |
---|---|---|---|---|
1.5L | 32.5kg | 405×386×512mm |
CHIKO AIRTEC CO., LTD
2-27-24, Hakunoshima, Minoh,
Osaka 562-0012 Japan
E-mail:info@chiko-airtec.jp