CHP-1200AT3

A high-pressure laser clean dust collector that can maintain a stable suction power for a long time, even under conditions where filter clogging is likely to occur, such as extraction of highly sticky fume generated by laser processing or handling a large amount of dust.

High pressure
AT3 panel
Dust removal function Pulse type
where is delivery date is specified when we delivery model that is compatible with ce standard
For Installation inside inside clean room
CHP-1200AT3
Slider

Filter cleaning function [Pulse type]

A proprietary continuous pulse air (compressed air) cleaning function is installed. The interval of the pulse can be adjusted easily.

Control panel

AT3 panel

See features page for more details.

Ethernet / RS-485

Option feature

All functions that can be operated on the AT3 panel can be operated by a PC with Ethernet or RS-485 communication.

Remote control

Remote cable

(sold separately/model: Using MT-173-8 (3 m) enables remote operation of peripheral equipment.

Motor cable receiving port on main body
  • 1.Operation input signal
  • 2.Operation pressure signal (DC1-5V)
  • 3.Filter clogging signal
  • 4.Remote-control operation switching input signal
  • 5.Operating signal
  • 6.Abnormality signal
  • 7.Change of operating level input signal (DC0-5V)
  • 8.Gnd
Operation ON/OFF
Change capacity level (air volume)

Primary filter

The zeolite is pre-coated by a proprietary scattering mechanism.

Filter is protected from clogging and a long filter life can be achieved even during the collection of fine dust and viscous fumes caused by laser processing. Teflon filter improve the peeling properties of the zeolite, fumes and dust.


Activated carbon

Deodorizing activated carbon can be installed as an option.

List of application

Extraction of fumes and dust during battery sealing process

Removal of dust and fumes from laser cutting lithium-ion battery electrodes

Removal of dust and fumes from laser cutting polarizing plate

Removal of dust from silicon isolator

Removal of dust when using laser cutting sheet for interior work

Easy primary filter chamber removal mechanism

When you remove the left and right snap locks and open the front cover, it turns into a slope and allow you to pull down the filter chamber easily with the levers on both side of the chamber.

Filter Type

Model Primary filter Secondary filter Exhaust HEPA filter Motor cooling filter Zeolite
suction exhaust
CHP-1200AT3 CS-200-500-75P-R x 4 CHF-3030-20 HEP-3535-69 PS/150N(215×115) CHF-3517-30 ZEO-2500(2.5kg)

List Of Specifications


Model Output Voltage Frequency Rated current
CHP-1200AT3 1200W 200V (single phase) 50/60Hz 11.0A
Maximum
air flow
Maximum
static pressure
Noise level

*1
Suction port
(hose) size
Compressed air
consumption volume
5.5㎥/min 13.5kPa  54-65dB φ100 24L/1 cycle
Compressed
air pressure
To be used
with 200-240V
CE  compliant Panel Power cable
0.3~0.4Mpa Standard AT3 3m
Filter cleaning function Remote control feature Suitable for use
in clean rooms

*2
Dust collection
volume capability

*3
Mass
Pulse type Level 10000 5.5L 110.0kg
Main body dimensions
(D×W×H)
568×577×1201.5mm
※1 Measurements obtained in Scale A (dBA) from a randomly selected position at a distance of 1m using a unit with a hose connected to its suction port.
(Pulse noise removed)
※2 Based on factory inspection data.
※3 As a reference, the dust collection capacity is about 70% of the amount that can be withdrawn.

 

Note:Contents may change without notice.